SYSTEM ROLE
The field-signal interface for an MPC4 protection card
The IOC4T installs at the rear of a VM600 rack, directly behind its corresponding MPC4. It transfers sensor inputs to the MPC4 through the rack backplane and returns processed signals to the field connections. Four dynamic measurement inputs and two tachometer inputs support machinery protection and basic condition monitoring.
Its three 16-contact terminal blocks separate dynamic inputs, speed and relay connections, and analog/control connections. Each dynamic channel has a software-configured DC output with a jumper-selected voltage or current format. Match the complete card PNR, hardware generation and receiving MPC4 before selecting a replacement.