SYSTEM ROLE
Shaft timing references for speed and phase measurements
The two-channel, half-height 3500/25 receives proximity-probe or magnetic-pickup signals and converts them into digital Keyphasor signals. These indicate a once-per-turn or multiple-event reference on a rotating shaft, allowing associated monitoring channels to relate their measurements to shaft timing.
A normal 3500 configuration accepts up to four Keyphasor signals. A paired arrangement supports up to eight signals subject to its primary/backup allocation and rack-position rules. The enhanced module is downward-compatible in form, fit and function and 149369-01 is listed as a direct plug-in replacement for the earlier 125792-01.