SYSTEM ROLE
Position measurements for machinery protection
The 3500/45 accepts up to four transducer signals, conditions them and compares configured measurements with user-programmable alarm setpoints. Supported functions include axial thrust position, differential expansion, ramp differential expansion, complementary input differential expansion, case expansion and valve position. The supported function depends on the selected transducer and rear I/O.
Channels are programmed in pairs: channels 1 and 2 share a function, as do channels 3 and 4. The module can therefore perform up to two configured functions simultaneously. The spare reference 176449-04 identifies the front Position Monitor; a matching rear I/O and the installed channel configuration are separate selection checks.