SYSTEM ROLE
Peak-to-peak shaft vibration to a 4–20 mA loop
The 990 conditions a single non-contacting 3300 NSv probe input into peak-to-peak vibration amplitude. Its integrated Proximitor sensor removes the need for a separate external sensor, while the two-wire current loop carries the proportional vibration signal to the receiving machinery control system.
990-04-70-02-00 selects range 04, system length 70, mounting 02 and approval option 00. Match the complete probe-and-cable chain to 7.0 m. The PROX OUT diagnostic signal is separate from the 4–20 mA trend output; alarm and protection logic are implemented in the receiving system.